+41 41 798 14 33 [email protected]
Icon
Swiss Tech Icon

Biocenter

The SalvisLab Biocenter is the ideal CO2 incubator for cell and tissue cultures.

The SalvisLab Biocenter is the ideal CO2 incubator for cell and tissue cultures. The innovative and reliable design concept ensures optimal conditions for your applications. The selected temperature control technology operates without any ventilation inside the chamber, thus reducing the risk of contamination to a minimum. Constant conditions for temperature, CO2 and humidity are kept independent from the load.

  • Easy touchscreen control
  • Decontamination at 200°C
  • Temperature uniformity is achieved by heating the chamber from all six sides
  • Infrared CO2 probe
  • Export process data to an SD card
  • Sealing inner glass door
  • Standard 25 mm entry port
  • Safety class 3.1
BC50
BC50
  • External dimensions (wxhxd) in mm: 535x705x430
  • Internal dimensions (wxhxd) in mm: 400x400x305
  • Internal volume (l): 50
  • Shelves (standard/max.): 3
  • Temp. range approx. >5°C oRt to (°C): 60
  • Temp. variation at 37°C (±°C): 0.2
  • Temp. fluctuation at 37°C (±°C): 0.1
  • CO2 range (%): 0–20
  • CO2 variation (±%): 0.1
  • CO2 fluctuation (±%): 0.2
  • CO2 recovery time 37°C (door open for 30 s, %/min.): >0.7
  • Waterbath (l): 1.5
  • Relative humidity 37°C (%): <95
  • Voltage (± 10%) 50/60Hz: 230
  • Ethernet port: Optional
  • Entry port (25 mm): Yes
  • O2 1–19% control: No

 

BC190
BC190
  • External dimensions (wxhxd) in mm: 850x765x600
  • Internal dimensions (wxhxd) in mm: 685x630x435
  • Internal volume (l): 190
  • Shelves (standard/max.): 4/8
  • Temp. range approx. >5°C oRt to (°C): 60
  • Temp. variation at 37°C (±°C): 0.25
  • Temp. fluctuation at 37°C (±°C): 0.1
  • CO2 range (%): 0.2–20
  • CO2 variation (±%): 0.2
  • CO2 fluctuation (±%): 0.2
  • CO2 recovery time 37°C (door open for 30 s, %/min.): >0.7
  • Waterbath (l): 1
  • Relative humidity 37°C (%): <95
  • Voltage (± 10%) 50/60Hz: 230
  • Ethernet port: Optional
  • Entry port (25 mm): Yes
  • O2 1–19% control: Optional

 

BC50 & BC190
  • 1–19% O2 control
  • Log software
  • Entry port 25 mm
  • RJ45 Port
  • Alarm contact
  • Inner glass door, 8 compartments (BC190)

 

BC50 & BC190
  • Perforated stainless steel shelves
  • Stacking kit and stand, with castors
  • Stacking kit (no stand)
  • Stand (no stacking kit) with four castors
  • Automatic CO2 cylinder change over unit (external)
  • CO2 filter (pack of two)
  • In-line CO2 reducing valve with pressure gauge
  • Two stage CO2 regulator
  • SD memory card

 

Download brochure

Download brochure